MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ejo/cjaf030

Медицинская библиотека · European journal of orthodontics · 2025

Assessing tooth mobility before and after miniscrew implantation for diagnosing root contact: a cadaveric animal study.

Oga Yasuhiko, Yamagata Keita, Kusumoto Junya, Miura Naoki, Miyawaki Shouichi

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine whether miniscrew-root contact can be diagnosed by assessing tooth mobility before and after miniscrew implantation.

MATERIALS AND

METHODS

Cadaveric pig mandibles were used, with 80 miniscrews placed mesial to the first premolars and distal to the fourth premolars. Maximum insertion torque (MIT) was measured for the first premolar miniscrews. Tooth mobility was assessed before and after implantation, and the Periotest Value difference (PTV-Diff) was calculated. Miniscrew-root distance (MS-R Dist) was measured using computed tomography. Spearman's rank correlations were analysed between MS-R Dist and PTV-Diff, and between MS-R Dist and MIT. Diagnostic efficacy was assessed using receiver-operating characteristic (ROC) curve analysis.

RESULTS

PTV-Diff exhibited a positive correlation with MS-R Dist (rs > 0.7, P < 0.001), confirming reduced tooth mobility when miniscrews contacted tooth roots. PTV-Diff demonstrated high diagnostic accuracy, with an area under the ROC curve > 0.9, outperforming MIT. Three observed root fractures influenced the correlation between MS-R Dist and PTV-Diff.

LIMITATIONS: The primary limitation is the use of cadaveric mandibles, allowing ideal perpendicular percussion with the Periotest system, which may be challenging to replicate in humans due to anatomical constraints.

CONCLUSION

Our results suggested that PTV-Diff effectively diagnoses miniscrew-root contact, outperforming MIT. Differences between first and fourth premolars emphasize the need for tooth-specific cut-off values in clinical applications. Root fractures significantly affected diagnostic accuracy, underscoring the importance of multiple PTV measurements during miniscrew placement. Measuring tooth mobility before and after miniscrew implantation may hold promise as a diagnostic approach for detecting miniscrew-root contact.

Для цитирования: Oga Yasuhiko, Yamagata Keita, Kusumoto Junya, Miura Naoki, Miyawaki Shouichi. Assessing tooth mobility before and after miniscrew implantation for diagnosing root contact: a cadaveric animal study.. European journal of orthodontics. 2025. DOI: 10.1093/ejo/cjaf030.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.