MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41372-024-01883-w

Медицинская библиотека · Journal of perinatology : official journal of the California Perinatal Association · 2024

Clinical and echocardiography predictors of response to first-line acetaminophen treatment in preterm infants with hemodynamically significant patent ductus arteriosus.

Moronta Stephania Cavallaro, Bischoff Adrianne R, Ryckman Kelli K, Dagle John M, Giesinger Regan E, McNamara Patrick J

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess clinical and echocardiography predictors of acetaminophen response for the treatment of patent ductus arteriosus (PDA) in preterm neonates.

STUDY

DESIGN

Retrospective cohort study of preterm infants born <30 weeks, with a diagnosis of hemodynamically significant PDA, who received 1st line treatment with intravenous acetaminophen during the first 2 postnatal weeks. Response was defined by PDA closure or improvement in PDA score of >50%.

RESULTS

A total of 100 infants were included whose median weight and gestational age at birth were 663 grams and 24.6 weeks respectively. In total, 66 infants were classified as responders and were more likely to have intrauterine growth restriction, exposure to maternal hypertension and chorioamnionitis. Non-response was more common among infants with thrombocytopenia and anemia.

CONCLUSION

Responders were more likely to be IUGR with echocardiography indices of lower preload. Response to 1st line intravenous acetaminophen therapy is comparable to non-steroidal drugs in preterm infants. Relationship of response to acetaminophen to perinatal characteristics requires further characterization.

Для цитирования: Moronta Stephania Cavallaro, Bischoff Adrianne R, Ryckman Kelli K, Dagle John M, Giesinger Regan E, McNamara Patrick J. Clinical and echocardiography predictors of response to first-line acetaminophen treatment in preterm infants with hemodynamically significant patent ductus arteriosus.. Journal of perinatology : official journal of the California Perinatal Association. 2024. DOI: 10.1038/s41372-024-01883-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.