OBJECTIVES

To test the hypotheses that (1) wearing a flexible wrist splint while taking an object from a box increases known postural risk factors for shoulder disorders and (2) that the height of the front of the box modulates the effect on shoulder kinematics of wearing a wrist splint.

DESIGN

A controlled laboratory experiment with 2 factors (splint wearing, box height).

SETTING

Human performance laboratory.

PARTICIPANTS

Ten consecutive healthy volunteers (5 men, 5 women; age range, 19-32 y).

INTERVENTIONS: Experimental manipulation of wrist immobilization and box height.

MAIN OUTCOME MEASURES: Humeral plane of elevation, humeral elevation, and humeral axial rotation.

RESULTS

Wearing a wrist splint increased the maximum humeral elevation angle (P<.001), and the height of the barrier also increased the maximum humeral elevation angle (P<.001). The average difference in maximum humeral elevation between the splint and the no splint conditions was 6.8 degrees .

CONCLUSIONS

Wearing a wrist splint while performing a job that requires removing objects from a box can increase risk factors for shoulder disorders. Workplace analysis should be performed to avoid secondary injuries before a patient wearing a wrist splint returns to work.

Для цитирования: Mell Amy G, Childress Brian L, Hughes Richard E. The effect of wearing a wrist splint on shoulder kinematics during object manipulation.. Archives of physical medicine and rehabilitation. 2005. DOI: 10.1016/j.apmr.2005.02.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.