DOI 10.1080/02713683.2023.2200915

Медицинская библиотека · Current eye research · 2023

Repeatability of Non-invasive Tear Film Evaluation in Healthy Rabbit Eyes.

Singh Swati, Srivastav Saumya, Thacker Minal, Bokara Kiran K, Singh Vivek, Basu Sayan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: The current study investigated the normative data values and repeatability of non-invasive tear film tests using Oculus Keratograph 5M in rabbit eyes.

METHODS

Triplicate analysis of tear film parameters [tear meniscus height (TMH), non-invasive tear break up time (NIBUT), bulbar congestion, meibography] of 38 healthy adults New Zealand white rabbits (mean age, 13 ± 4.7 months) was performed using Oculus keratograph 5M (K5M). Bland-Altman analysis was used for testing repeatability.

RESULTS

Thirty-eight rabbits (N = 76 eyes) weighing 2.5 ± 0.4 kg were studied. The mean NIBUT values of the right and left eye were 14.3 ± 5.8 and 12.3 ± 5.8 s, respectively. The mean central TMH values were 0.43 ± 0.23 and 0.33 ± 0.14 mm in the right and left eye, respectively. Meibography showed closely placed, wide meibomian glands running vertically with no distorted or gland loss areas. There were no differences between the eyes for the above parameters. Bland-Altman plot showed good repeatability for both NIBUT and TMH values.

CONCLUSION

The non-invasive tear film parameters show good repeatability using keratograph 5M and can be used as an objective parameter for rabbit ocular surface experiments.

Для цитирования: Singh Swati, Srivastav Saumya, Thacker Minal, Bokara Kiran K, Singh Vivek, Basu Sayan. Repeatability of Non-invasive Tear Film Evaluation in Healthy Rabbit Eyes.. Current eye research. 2023. DOI: 10.1080/02713683.2023.2200915.