Медицинская библиотека · Journal of clinical medicine · 2024

Efficacy of the Sub-Urethral Transobturator KIM System® for Female Urinary Incontinence: Long Term Results.

Lorenzo-Gómez María-Fernanda, Flores-Carvajal Javier-Antonio, Márquez-Sánchez Magaly-Teresa, Márquez-Sánchez Gerardo-Alfonso, Flores-Fraile Javier, Alves-Rodrigues Filipa-María, Miron-Canelo Jose-Antonio, Padilla-Fernández Bárbara Yolanda

СтатьяПеревод в очереди

Аннотация

Background/

Objectives

Female stress urinary incontinence (SUI) surgical treatment has changed since its beginning. Selecting materials that promote constructive tissue remodelling helps to maintain continence after surgery and minimizes complications. To analyze the long-term urinary continence results in women who underwent SUI surgical correction using the transobturator mid-urethral sling KIM system® (Knotless Incontinence Mesh) and analyze the complications associated with this SUI treatment. Materials and

Methods

Prospective study of the first 1000 patients undergoing SUI surgery with the Contasure KIM® sling between April 2007 and December 2018. Results and complications were recorded. Group A represented 94.2% of the sample and were the continent patients after surgery (GA = 942), while Group B accounted for incontinent patients after surgery (5.8%) (GB = 58).

Results

The mean age at operation was 60 years. Eutocic deliveries (p = 0.0022), high blood pressure (p = 0.0190), anxiety (p = 0.0084), hemorrhoidectomies (p = 0.0016) and hysterectomies (p = 0.0002) were higher in GB. No differences between groups were found regarding body mass index (GA 26.50; GB 26.93) (p = 0.220649), food or drug allergies (p = 0.0.6547), dystocia (p = 0.2365), diabetes mellitus (p = 0.1715), pelvic surgery (p = 0.8842), other surgery (p = 0.8801) or concomitant treatments that would have an impact on bladder function. Correction of SUI was achieved in 94.2% of cases. Continence persisted over time in 97.98% of continent patients at 4-year follow-up and 90.90% of patients at last follow-up. Mesh caused erosion of the urethra in 0.3% of patients and extruded to the vagina in 0.42%. De novo urinary urgency (2.8%), significant chronic pain (3.6%) and urinary tract infections (3.0%) after surgery were lower than complications reported in reviewed publications. Pain was treated with medication, and all patients were pain-free at the one-year follow-up visit.

Conclusions

The mid-urethral transobturator sling KIM system® has good initial and long-term results in patients with stress urinary incontinence, with a low recurrence rate and minimal complications.

Для цитирования: Lorenzo-Gómez María-Fernanda, Flores-Carvajal Javier-Antonio, Márquez-Sánchez Magaly-Teresa, Márquez-Sánchez Gerardo-Alfonso, Flores-Fraile Javier, Alves-Rodrigues Filipa-María, Miron-Canelo Jose-Antonio, Padilla-Fernández Bárbara Yolanda. Efficacy of the Sub-Urethral Transobturator KIM System® for Female Urinary Incontinence: Long Term Results.. Journal of clinical medicine. 2024. DOI: 10.3390/jcm13195728.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.