MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/0029-7844(96)00020-8

Медицинская библиотека · Obstetrics and gynecology · 1996

The efficacy of individual computer heart rate indices in detecting acidemia at birth in growth-restricted fetuses.

Guzman E R, Vintzileos A M, Martins M, Benito C, Houlihan C, Hanley M

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine the efficacy of individual fetal heart rate (FHR) indices, as determined by computer analysis of the FHR tracing, in detecting fetal acidemia at birth in growth-restricted fetuses.

METHODS

The study population consisted of 38 growth-restricted fetuses at 26-37 weeks' gestation from pregnancies with abnormal uterine and/or umbilical artery Doppler velocimetry. The 1-hour FHR tracing was analyzed by computer within 4 hours of cesarean birth before the onset of labor. Umbilical artery cord blood was collected at birth, and pH was determined within 5 minutes of collection.

RESULTS

On linear regression, the duration of episodes of low variation in minutes (r = -0.77, r2 = 0.59) and short-term (r = 0.72, r2 = 0.52) and long-term (r = 0.69, r2 = 0.47) variation in milliseconds were significantly related to umbilical artery pH at birth, and more so than the number of accelerations of ten (r = 0.57, r2 = 0.32) and 15 (r = 0.38, r2 = 0.14) beats per minute. There were significant differences in computer measurements of FHR accelerations and variation between the umbilical artery pH categories of acidemia (pH less than 7.20), preacidemia (7.20-7.25), and nonacidemia (greater than 7.25). Stepwise regression revealed that episodes of low variation best described the model for predicting umbilical artery pH at birth (P < .001), with no improvement provided by the addition of other computer-analyzed FHR characteristics.

CONCLUSION

In this population of growth-restricted fetuses delivered by elective cesarean, the computer indices of duration of episodes of low variation and short-term and long-term variation were significantly associated with umbilical artery pH and predicted umbilical artery acidemia at birth.

Для цитирования: Guzman E R, Vintzileos A M, Martins M, Benito C, Houlihan C, Hanley M. The efficacy of individual computer heart rate indices in detecting acidemia at birth in growth-restricted fetuses.. Obstetrics and gynecology. 1996. DOI: 10.1016/0029-7844(96)00020-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.