MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00192-022-05342-y

Медицинская библиотека · International urogynecology journal · 2022

Validation of an ovine vesicovaginal fistula model.

Maljaars Lennart P, Jeffery Stephen T, Scholten Marlou, Kaestner Lisa, Jere Khumbo, Bezuidenhout Deon, Guler Zeliha, Roovers Jan-Paul W R

СтатьяПеревод в очереди

Аннотация

INTRODUCTION AND HYPOTHESIS: A representative, large animal model of vesicovaginal fistulas is needed for the training of surgeons and for the development of new surgical techniques and materials for obstetric fistula repair.

METHODS

The safety, feasibility, and reproducibility of vesicovaginal fistula creation were studied in 4 adult female sheep. A 1-cm fistula was created between the vagina and the bladder through a transvaginal approach. The defect was allowed to heal for 8 weeks and the animals were then euthanized. The primary outcome was the fistula patency. Secondary outcomes were fistula size, urogenital dimensions, urodynamic evaluation, histology (inflammation, vascularization, collagen deposition) and biomechanical characteristics of the fistula edge (stress at break, maximum elongation, and stiffness).

RESULTS

The transvaginal creation of a vesicovaginal fistula was safe. All animals survived the surgical procedure and follow-up period, without complications. Three of the four animals demonstrated a patent vesicovaginal fistula after 8 weeks. Baseline data are provided of the urogenital dimensions and the urodynamic, histological, and biomechanical characteristics of the model.

CONCLUSIONS

The ewe is a safe, feasible, and reproducible model for vesicovaginal fistulas. The model can help to study new techniques and materials to boost surgical innovation for vesicovaginal fistula repair.

Для цитирования: Maljaars Lennart P, Jeffery Stephen T, Scholten Marlou, Kaestner Lisa, Jere Khumbo, Bezuidenhout Deon, Guler Zeliha, Roovers Jan-Paul W R. Validation of an ovine vesicovaginal fistula model.. International urogynecology journal. 2022. DOI: 10.1007/s00192-022-05342-y.