DOI 10.11604/pamj.2022.42.175.35808
[Endoscopic removal of intrauterine device perforating the sigmoid colon: case report].
Аннотация
Intrauterine device (IUD) is the mainstay of family planning methods in developing countries. However, it is associated with severe complications such as bleeding, perforation and migration to adjacent organs. Although perforation of the uterus is not rare, migration to the sigmoid colon is exceptional. We here report a case of IUD migration into sigmoid colon; this was removed via low endoscopy. The study involved a 45-year-old woman using an IUD who presented with pelvic pain associated with a feeling of pelvic heaviness 6 years later of insertion. Clinical examination was without abnormalities, and computed tomography (CT) scan showed the IUD embedded in the sigmoid colon wall. Diagnostic and therapeutic laparoscopy was performed, which objectified IUD-related intestinal perforation. IUD was partially embedded in the sigmoid colon wall and couldn't be removed. The device was removed during colonoscopy by diathermy loop excision (15 mm in diameter).