PURPOSE: Assess the relationship between optic nerve sheath diameter (ONSD) measured on bedside portable computed tomography (CT) scans and simultaneously measured intracranial pressure (ICP) in patients with severe traumatic brain injury.

METHODS

Retrospective cohort study of 57 patients admitted between 2009 and 2013. Linear and logistic regression were used to model the correlation and discrimination between ONSD and ICP or intracranial hypertension, respectively.

RESULTS

The cohort had a mean age of 40 years (SD 16) and a median admission Glasgow coma score of 7 (IQR 4-10). The between-rater agreement by intraclass coefficient was 0.89 (95 % CI 0.83-0.93, P < 0.001). The mean ONSD was 6.7 mm (SD 0.75) and the mean ICP during CT was 21.3 mmHg (SD 8.4). Using linear regression, there was a strong correlation between ICP and ONSD (r = 0.74, P < 0.001). ONSD had an area under the curve to discriminate elevated ICP (≥20 mmHg vs. <20 mmHg) of 0.83 (95 % CI 0.73-0.94). Using a cutoff of 6.0 mm, ONSD had a sensitivity of 97 %, specificity of 42 %, positive predictive value of 67 %, and a negative predictive value of 92 %. Comparing linear regression models, ONSD was a much stronger predictor of ICP (R(2) of 0.56) compared to other CT features (R(2) of 0.21).

CONCLUSIONS

Simultaneous measurement of ONSD on CT and ICP were strongly correlated and ONSD was discriminative for intracranial hypertension. ONSD was much more predictive of ICP than other CT features. There was excellent agreement between raters in measuring ONSD.

Для цитирования: Sekhon Mypinder S, Griesdale Donald E, Robba Chiara, McGlashan Nick, Needham Edward, Walland Katherine, Shook Alyssa C, Smielewski Peter, Czosnyka Marek, Gupta Arun K, Menon David K. Optic nerve sheath diameter on computed tomography is correlated with simultaneously measured intracranial pressure in patients with severe traumatic brain injury.. Intensive care medicine. 2014. DOI: 10.1007/s00134-014-3392-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.