Fluoroscopic manipulation of peritoneal dialysis catheters: outcomes and factors associated with successful manipulation.

Miller Matthew, McCormick Brendan, Lavoie Susan, Biyani Mohan, Zimmerman Deborah

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

Mechanical failure of the peritoneal dialysis (PD) catheter is an important cause of technique failure. Fluoroscopic guidewire manipulation may be undertaken in an attempt to correct the failure. The purpose of this study was to determine the efficacy of fluoroscopic manipulation of previously embedded PD catheters, the factors associated with successful manipulation, and the complication rate associated with manipulation.

DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: A single-center, retrospective review of 70 consecutive PD patients undergoing fluoroscopic manipulation for mechanical failure of their PD catheter from June 2006 to February 2011 was undertaken. Logistic regression models were developed to determine the variables associated with successful manipulation.

RESULTS

Of the 70 manipulations, 44 were successful (62.9%). In univariate analysis, catheters located in the pelvis compared with those in the upper abdomen (73.5% versus 42.9%, P=0.01) and catheters that were previously functional compared with those that failed at exteriorization (75.0% versus 46.7%, P=0.04) were more likely to be successfully manipulated. Time embedded, previous hemodialysis, and number of intra-abdominal surgeries were not correlated with likelihood of successful manipulation. In multivariate analysis, catheters located in the pelvis (P=0.01) and those with secondary failure (P=0.01) were more likely to successfully manipulated. Two of the patients developed peritonitis (2.9%), neither requiring cessation of PD.

CONCLUSIONS

Fluoroscopic manipulation is an effective and safe therapy for failed PD catheters that are unresponsive to conservative treatment. Properly positioned catheters and those that were previously functional are more likely to be successfully manipulated.

Для цитирования: Miller Matthew, McCormick Brendan, Lavoie Susan, Biyani Mohan, Zimmerman Deborah. Fluoroscopic manipulation of peritoneal dialysis catheters: outcomes and factors associated with successful manipulation.. Clinical journal of the American Society of Nephrology : CJASN. 2012. DOI: 10.2215/cjn.09850911.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.