OBJECTIVE

We describe a novel and safe technique using a 12F-14F pediatric arterial cannula to establish unilateral, selective, antegrade cerebral perfusion (ACP) during open hemiarch reconstruction.

METHODS

Between January 2015 and September 2018, 42 patients underwent elective aortic aneurysm repair requiring an open distal anastomosis and at least a hemiarch replacement via hypothermic circulatory arrest by 2 surgeons. All distal reconstructions were performed at moderate hypothermia (22°C-26°C) with direct cannulation of the innominate artery (IA) using a pediatric arterial cannula to allow ACP at 10-15 mL/kg/min. Data were collected by retrospective chart review.

RESULTS

Thirty-one of the 42 patients (74%) were male. The mean patient age was 65 ± 13 years, and the mean body surface area was 2.1 ± 0.3 m2. Proximal repairs included a modified Bentall with a valve-graft composite (n = 17), valve-sparing root replacement (n = 2), and aortic valve replacement (n = 15). Perioperative mortality was 2% (n = 1), and the incidence of stroke was 0%. The mean lowest core body temperature reached during circulatory arrest was 23.8 ± 2.7°C with a mean ACP time of 21.8 ± 3.6 minutes. The mean aortic cross-clamp and cardiopulmonary bypass times were 160.6 ± 55.5 minutes and 204.7 ± 57.5 minutes, respectively. There were no cases of IA injury.

CONCLUSIONS

Direct IA cannulation with a pediatric arterial cannula is a safe and efficient method to allow ACP in aortic surgery requiring hypothermic circulatory arrest and may circumvent the potential complications of axillary cannulation.

Для цитирования: Wai Sang Stephane Leung, Beute Tyler J, Timek Tomasz. A simple method to establish antegrade cerebral perfusion during hemiarch reconstruction.. JTCVS techniques. 2020. DOI: 10.1016/j.xjtc.2020.03.012.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.