MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0363546514561435

Медицинская библиотека · The American journal of sports medicine · 2014

MRI volume and signal intensity of ACL graft predict clinical, functional, and patient-oriented outcome measures after ACL reconstruction.

Biercevicz Alison M, Akelman Matthew R, Fadale Paul D, Hulstyn Michael J, Shalvoy Robert M, Badger Gary J, Tung Glenn A, Oksendahl Heidi L, Fleming Braden C

Контролируемое клиническое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Clinical, functional, and patient-oriented outcomes are commonly used to evaluate the efficacy of treatments after anterior cruciate ligament (ACL) injury; however, these evaluation techniques do not directly measure the biomechanical changes that occur with healing.

PURPOSE: To determine if the magnetic resonance (MR) image-derived parameters of graft volume and signal intensity (SI), which have been used to predict the biomechanical (ie, structural) properties of the graft in animal models, correlate with commonly used clinical (anteroposterior [AP] knee laxity), functional (1-legged hop), and patient-oriented outcome measures (Knee Injury and Osteoarthritis Outcome Score [KOOS]) in patients 3 and 5 years after ACL reconstruction.

STUDY

DESIGN

Cohort study (diagnosis); Level of evidence, 3.

METHODS

Based on a subset of participants enrolled in an ongoing ACL reconstruction clinical trial, AP knee laxity, 1-legged hop test, and KOOS were assessed at 3- and 5-year follow-up. Three-dimensional, T1-weighted MR images were collected at each visit. Both the volume and median SI of the healing graft were determined and used as predictors in a multiple regression linear model to predict the traditional outcome measures.

RESULTS

Graft volume combined with median SI in a multiple linear regression model predicted 1-legged hop test at both the 3- and 5-year follow-up visits (R(2) = 0.40, P = .008 and R(2) = 0.62, P = .003, respectively). Similar results were found at the 5-year follow-up for the KOOS quality of life (R(2) = 0.49, P = .012), sport/function (R(2) = 0.37, P = .048), pain (R(2) = 0.46, P = .017), and symptoms (R(2) = 0.45, P = .021) subscores, although these variables were not significant at 3 years. The multiple linear regression model for AP knee laxity at 5-year follow-up approached significance (R(2) = 0.36, P = .088).

CONCLUSION

The MR parameters (volume and median SI) used to predict ex vivo biomechanical properties of the graft in an animal model have the ability to predict clinical or in vivo outcome measures in patients at 3- and 5-year follow-up.

CLINICAL RELEVANCE: Results from this study may enhance clinical evaluation of graft health by relating the MR parameters of volume and median SI to traditional outcome measures and could potentially aid researchers in determining the appropriate timing for athletes to return to sport.

Для цитирования: Biercevicz Alison M, Akelman Matthew R, Fadale Paul D, Hulstyn Michael J, Shalvoy Robert M, Badger Gary J, Tung Glenn A, Oksendahl Heidi L, Fleming Braden C. MRI volume and signal intensity of ACL graft predict clinical, functional, and patient-oriented outcome measures after ACL reconstruction.. The American journal of sports medicine. 2014. DOI: 10.1177/0363546514561435.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.