Медицинская библиотека · The Journal of bone and joint surgery. American volume · 2020

Improved Detection of Scaphoid Fractures with High-Resolution Peripheral Quantitative CT Compared with Conventional CT.

Daniels A M, Bevers M S A M, Sassen S, Wyers C E, van Rietbergen B, Geusens P P M M, Kaarsemaker S, Hannemann P F W, Poeze M, van den Bergh J P, Janzing H M J

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Computed tomography (CT), magnetic resonance imaging, and bone scintigraphy are second-line imaging techniques that are frequently used for the evaluation of patients with a clinically suspected scaphoid fracture. However, as a result of varying diagnostic performance results, no true reference standard exists for scaphoid fracture diagnosis. We hypothesized that the use of high-resolution peripheral quantitative CT (HR-pQCT) in patients with a clinically suspected scaphoid fracture could improve scaphoid fracture detection compared with conventional CT in the clinical setting.

METHODS

The present study included 91 consecutive patients (≥18 years of age) who presented to the emergency department with a clinically suspected scaphoid fracture between December 2017 and October 2018. All patients were clinically reassessed within 14 days after first presentation, followed by CT and HR-pQCT. If a scaphoid fracture was present, the fracture type was determined according to the Herbert classification system and correlation between CT and HR-pQCT was estimated with use of the Kendall W statistic or coefficient of concordance (W) (the closer to 1, the higher the correlation).

RESULTS

The cohort included 45 men and 46 women with a median age of 52 years (interquartile range, 29 to 67 years). HR-pQCT revealed a scaphoid fracture in 24 patients (26%), whereas CT revealed a scaphoid fracture in 15 patients (16%). Patients with a scaphoid fracture were younger and more often male. The correlation between CT and HR-pQCT was high for scaphoid fracture type according to the Herbert classification system (W = 0.793; 95% confidence interval [CI], 0.57 to 0.91; p < 0.001) and very high for scaphoid fracture location (W = 0.955; 95%, CI 0.90 to 0.98; p < 0.001).

CONCLUSIONS

In the present study, the number of patients diagnosed with a scaphoid fracture was 60% higher when using HR-pQCT as compared with CT. These findings imply that a substantial proportion of fractures-in this study, more than one-third-will be missed by the current application of CT scanning in patients with a clinically suspected scaphoid fracture.

LEVEL OF EVIDENCE: Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Daniels A M, Bevers M S A M, Sassen S, Wyers C E, van Rietbergen B, Geusens P P M M, Kaarsemaker S, Hannemann P F W, Poeze M, van den Bergh J P, Janzing H M J. Improved Detection of Scaphoid Fractures with High-Resolution Peripheral Quantitative CT Compared with Conventional CT.. The Journal of bone and joint surgery. American volume. 2020. DOI: 10.2106/jbjs.20.00124.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.