MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jviromet.2024.114889

Медицинская библиотека · Journal of virological methods · 2024

Visual, rapid, and cost-effective BK virus detection system for renal transplanted patients using gold nanoparticle coupled loop-mediated isothermal amplification (nanoLAMP).

Kumar Sunil, Raman Srishty, Sesham Kishore, Gupta Abhishek, Yadav Raj Kanwar, Mridha Asit Ranjan, Yadav Subhash Chandra

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A substantial percentage of kidney transplant recipients show transplant failure due to BK virus-induced nephropathy. This can be clinically controlled by the rapid and timely detection of BK virus infection in immune-compromised patients. We report a rapid (two hours from sample collection, processing, and detection), cost-effective (< 2$), highly sensitive and BKV-specific nanoLAMP (loop-mediated isothermal amplification) diagnostic methodology using novel primers and gold nanoparticles complex-based visual detection. The standardized nanoLAMP showed an analytical sensitivity of 25 copies/µl and did not cross-react with closely related JC and SV40 viruses. This nanoLAMP showed diagnostic sensitivity and specificity as 91% and 96%, respectively, taking 50 BK virus-negative (confirmed by qPCR from the plasma of healthy donors) and 57 positive BKV patient samples (confirmed by clinical parameters and qPCR assay). This simple two-step, low-cost, and quick (1-2 h/test) detection would be advantageous over the currently used diagnostic methodology. It may change the paradigm for polyomavirus infection-based failure of renal transplant.

Для цитирования: Kumar Sunil, Raman Srishty, Sesham Kishore, Gupta Abhishek, Yadav Raj Kanwar, Mridha Asit Ranjan, Yadav Subhash Chandra. Visual, rapid, and cost-effective BK virus detection system for renal transplanted patients using gold nanoparticle coupled loop-mediated isothermal amplification (nanoLAMP).. Journal of virological methods. 2024. DOI: 10.1016/j.jviromet.2024.114889.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.