DOI 10.1186/s12891-020-03784-3
The pathological features of hip abductor tendon tears - a cadaveric study.
Аннотация
BACKGROUND
The hip abductors are crucial in maintaining pelvic stability. Tears in these tendons are common and often debilitating. There is uncertainty regarding both the histological and macroscopic features of hip abductor tears. This study aims to clarify both the macroscopic and microscopic features of the tendon and enthesis in hip abductor tendon tears.
METHODS
Thirty-six cadavers with an average age of 81 were dissected, and the hip abductor mechanisms removed en-bloc. The presence, location and size of the tears were recorded and analysed. The samples were processed into histological blocks and viewed using both transmitted and polarised light. Tendon histology was graded using the modified Movin's score in three sections (deep, middle and superficial layers) and the enthesis graded separately using 5-point criteria. Analysis of variance was used to confirm histological features associated with tears.
RESULTS
Tears were found in 24 of 36 samples (67%). The most common finding was an isolated tear in the gluteus minimus (46%), followed by concurrent gluteus medius and gluteus minimus tears (33%). Histology revealed significantly more degeneration in both the tendon (p = 0.0005) and enthesis (p = 0.0011) when tears were present. Furthermore, these changes were concentrated in the deeper layers of the tendon (p = 0.0002) and enthesis (p = 0.003).
CONCLUSION
This study demonstrated degeneration as the primary pathology underlying hip abductor tendon tears. Degenerative changes occur in both the tendon and enthesis, with the deeper layers predominantly affected. These findings are important for guiding surgical repair techniques and to aid the development of novel materials and biologics.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.