Fracture Repair in Cats Using a Conical Coupling Mini 1.9 to 2.5 mm Locking Plate System.

Ferrero Francesca C, Baroncelli Alessandro Boero, Hudson Caleb C, Peirone Bruno, Reif Ullrich, Piras Lisa A

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

OBJECTIVE

The aim of this study was to retrospectively evaluate the clinical application of the Fixin mini 1.9 to 2.5 system for the treatment of long bone fractures in cats. We proposed that the Fixin mini system would successfully stabilize long bone fractures in cats with a healing time and complication rate similar to those previously reported for feline fractures using other locking bone plate systems.

MATERIALS AND

METHODS

Medical records and radiographs of cats with long bone fractures stabilized with the Fixin mini 1.9 to 2.5 system were retrospectively reviewed. Signalment, body weight, bone(s) fractured, region of bone fractured, fracture classification, concurrent orthopaedic injuries, complications, time to functional union, if minimally invasive plate osteosynthesis techniques were used, plate size, number of plates, bone graft use and ancillary methods of fixation were recorded.

RESULTS

Fifty-six fractures in 54 cats were included. Mean time to radiographic union was 8.8 weeks. Complications were recorded in 8 out of 56 fractures. Major complications occurred in 4 of 56 fractures and minor complications occurred in 4 of 56 fractures.

CONCLUSION

The Fixin mini 1.9 to 2.5 system had an overall complication rate and time to functional union similar to that of other implant systems used to treat feline long bone fractures and it appears suitable for repair of a wide variety of long bone fracture configurations in cats.

Для цитирования: Ferrero Francesca C, Baroncelli Alessandro Boero, Hudson Caleb C, Peirone Bruno, Reif Ullrich, Piras Lisa A. Fracture Repair in Cats Using a Conical Coupling Mini 1.9 to 2.5 mm Locking Plate System.. Veterinary and comparative orthopaedics and traumatology : V.C.O.T. 2020. DOI: 10.1055/s-0040-1713005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.