MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jogoh.2019.101666

Медицинская библиотека · Journal of gynecology obstetrics and human reproduction · 2019

A pilot study of a novel technique for hysteroscopic sterilization using the distal ends of a copper-T intrauterine device (Ostialoc).

Dawood Ayman Shehata, Abbas Ahmed M, Elgergawy Adel

СтатьяОтозванная публикацияПеревод в очереди
Источник пометил публикацию как отозванную.

Аннотация

OBJECTIVE

To describe the feasibility and effectiveness of a novel technique for Hysteroscopic sterilization using the distal ends of a copper-T intrauterine device (Ostialoc).

PATIENT AND

METHODS

A pilot study included 11 cases selected and informed about the technique at a tertiary University hospital. Through hysteroscopy, the knobs with the distal 1 cm of Copper-T intrauterine devices (Ostialoc) were inserted into the interstitial part of both fallopian tubes for the tubal block. Patients were evaluated two weeks later by plain X-ray and ultrasound to ensure nonexpulsion of the Ostialoc, then every month for three successive months. The patients were scheduled for HSG at 3 months and one year after the Ostialoc placement to evaluate tubal occlusion.

RESULTS

The mean age of cases was 39.20 ± 4.09 years, mean parity was 4.48 ± 1.00, and the mean BMI was 28.92 ± 4.31 Kg/m2. The mean operative time was 22.24 ± 5.63 min. The technique was feasible in all cases. The postoperative complications were present in one case suffered from pelvic pain. HSG demonstrated complete block of both fallopian tubes after three months and at one year in 100% of the cases.

CONCLUSION

Hysteroscopic sterilization using Ostialoc technique seems to be a feasible and effective technique in low resources countries.

Для цитирования: Dawood Ayman Shehata, Abbas Ahmed M, Elgergawy Adel. A pilot study of a novel technique for hysteroscopic sterilization using the distal ends of a copper-T intrauterine device (Ostialoc).. Journal of gynecology obstetrics and human reproduction. 2019. DOI: 10.1016/j.jogoh.2019.101666.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.