MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.acra.2026.06.037

Медицинская библиотека · Academic radiology · 2026

Explainable Machine-learning Model Based on Multimodal Ultrasound for Non-invasive Detection of Early Renal Fibrosis: A Multicenter Study.

Zhang Yao, Huang Xingyue, Xu Wei, Liu Wen, Zhou Chang, Shen Dian, Yan Wenkai, Jin Yanping, Zhao Xianwei, Li Rui, Hu Yafei, Xiang Yi, Tao Yichao, Ding Xuejiao, Ye Huarong, Lei Bingsong, Gan Ling, Yang Juan, Zhang Wenjun, Gong Xinde, Hu Zhian, Rao Xiangang, Peng Yuexiang, Zhou Changhua, Wang Yi, Wang Xiang, Mei Jing, Wu Jin, Yan Wei, Xu Long, Tang Xinliang, Chen Shi, Deng Qing, Zhou Qing

СтатьяМногоцентровое исследованиеВалидационное исследованиеПеревод в очереди

Аннотация

RATIONALE AND

OBJECTIVES

To develop and validate an interpretable, multimodal, ultrasound-based machine-learning (ML) model for the non-invasive identification of early renal fibrosis in patients with chronic kidney disease (CKD).

MATERIALS AND

METHODS

In this prospective, multicenter study, 369 participants (healthy controls, n = 161; mild fibrosis, n = 208) were recruited from 16 institutions. Mild fibrosis was defined by histopathological grading. Six ML algorithms were evaluated, and multiple models were constructed using different combinations of conventional ultrasound, ultra micro angiography (UMA), shear-wave elastography (SWE), super-resolution ultrasound (SRUS), and clinical variables; performance was compared in terms of discrimination, calibration, and clinical utility. External validation was conducted using held-out centers. Model interpretability was examined using Shapley Additive exPlanations (SHAP).

RESULTS

In the internal dataset, the comprehensive fusion model integrating SRUS, SWE, conventional ultrasound, and clinical variables, based on Light Gradient Boosting Machine, achieved an area under the curve (AUC) of 0.948 (accuracy, 0.880; sensitivity, 0.987). In the external dataset, it maintained good generalization (AUC, 0.823; accuracy, 0.748; sensitivity, 0.883). The fusion model outperformed the clinical baseline model in both internal and external validations (internal AUC, 0.732; external AUC, 0.650). SHAP analysis identified both imaging parameters (vessel density, fractal dimension) and clinical indices (serum creatinine (Scr), estimated glomerular filtration rate (eGFR)) as key predictors, consistent with pathophysiological changes of early fibrosis.

CONCLUSION

An explainable multimodal ultrasound-based ML model showed promising performance for the non-invasive identification of early renal fibrotic changes and may support adjunctive risk stratification in CKD.

Для цитирования: Zhang Yao, Huang Xingyue, Xu Wei, Liu Wen, Zhou Chang, Shen Dian, Yan Wenkai, Jin Yanping, Zhao Xianwei, Li Rui, Hu Yafei, Xiang Yi, Tao Yichao, Ding Xuejiao, Ye Huarong, Lei Bingsong, Gan Ling, Yang Juan, Zhang Wenjun, Gong Xinde, Hu Zhian, Rao Xiangang, Peng Yuexiang, Zhou Changhua, Wang Yi, Wang Xiang, Mei Jing, Wu Jin, Yan Wei, Xu Long, Tang Xinliang, Chen Shi, Deng Qing, Zhou Qing. Explainable Machine-learning Model Based on Multimodal Ultrasound for Non-invasive Detection of Early Renal Fibrosis: A Multicenter Study.. Academic radiology. 2026. DOI: 10.1016/j.acra.2026.06.037.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.