m+Medelevator.RU
← Поиск публикаций
JSES reviews, reports, and techniques · 2024

Comparing internal and external stabilization for traumatic elbow instability: a systematic review.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Heifner John J, Davis Ty A, Rowland Robert J, Gomez Osmanny, Gray Robert R L

Аннотация

BACKGROUND: Despite surgical reestablishment of the supporting structures, instability may often persist in traumatic elbow injury. In these cases, a temporary internal or external fixator may be indicated to unload the repaired structures and maintain joint concentricity. Aggregate data are needed to characterize the risk of complication between external fixation (ExFix) and the internal joint stabilizer (IJS) when used for traumatic elbow instability. Our objective was to review the literature to compare the complication profile between external fixation and the IJS.

METHODS: A database query was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The Population, Intervention, Comparison and Outcome characteristics for eligibility were the following: for patients over 18 years clinical outcomes were compared between an ExFix or the IJS for acute or chronic elbow instability. The Cochran risk of bias in nonrandomized studies of interventions and grades of recommendation, assessment, development, and evaluation framework were compiled for risk of bias and quality assessment.

RESULTS: The rate of recurrent instability was 4.1% in the IJS group (N = 171) and 7.0% in the ExFix group (N = 435), with an odds ratio of 1.93 (95% confidence interval 0.88-4.23). The rate of device failure was 4.4% in the IJS group and 4.1% in the ExFix group. Pin-related complications occurred in 14.6% of ExFix cases. Complications in the IJS group were the following: 1 case of inflammatory reaction, 4 cases of post removal surgical site infection, and 5 symptomatic removals.

DISCUSSION: The literature demonstrates a distinct difference in complication profile between external fixation and the IJS when used as treatment for traumatic elbow instability. Although not statistically significant, the higher rate of recurrent instability following external fixation may be clinically important. The high rate of pin-related complications with external fixation is notable.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты