BACKGROUND

Suture bridge repair has been widely used as one of the standard procedures in the arthroscopic rotator cuff repair. We compared the intratendinous stress distribution between single and double suture passing techniques in the suture bridge repair using a 2-mm tape and clarified the roles of tensioning in this procedure.

METHODS

A board-like model of the supraspinatus tendon and humeral head was used in order to standardize conditions and exclude the influence of anatomical variations between individuals. Reattachment of the supraspinatus tendon to the bone was simulated using both single and double suture passing techniques for the suture bridge repair using a 2-mm tape. A tensile load was applied to the medial end of the tendon, and the stress distribution pattern was observed. Elastic analysis enabled comparison of the von Mises equivalent and maximum principal stresses between the single and double suture passing techniques. The tape configuration was subsequently translated 1 mm toward the insertion points of lateral anchors to simulate the tensioning maneuver.

RESULTS

Although the distribution pattern of both the equivalent and the maximum principal stresses was similar for both models, areas with a high stress concentration were smaller in the single suture passing model than those in the double suture passing model. The equivalent stress concentrated within the tendon beneath the tapes as well as in the area between the crossing tapes and the lateral end of the tendon, whereas the maximum principal stress concentrated medial to the sites of suture penetration.

CONCLUSIONS

Single suture passing technique can reduce the extent of intratendinous stress concentration compared with double suture passing technique, which might be beneficial to reduce the incidence of type 2 retear after suture bridge repair of rotator cuff tendon using a 2-mm tape.

Для цитирования: Sano Hirotaka, Komatsuda Tatsuro, Inawashiro Takashi, Sasaki Daizo, Noguchi Moriyuki, Irie Taichi, Abe Hiroo, Ozawa Hiroshi, Yokobori A Toshimitsu. Comparison between single and double suture passing techniques in the suture bridge rotator cuff repair with a 2-mm tape: A simulation study using a three-dimensional finite element method.. Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association. 2020. DOI: 10.1016/j.jos.2020.02.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.