m+Medelevator.RU
← Поиск публикаций
Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2026

Diagnostic Performance of Duplex Ultrasonography in Post-Radiation Common Carotid Artery Stenosis: A Cross-Sectional Validation Study.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chen Min-Shuo, Jiang Jian-Lin, Yeh Chih-Hua, Chang Ting-Yu, Chang Joseph Tung-Chieh, Huang Bing-Shen, Lin Chien-Yu, Wu Yi-Ming, Chang Chun-Wei, Chang Yeu-Jhy, Wu Hsiu-Chuan, Lee Tsong-Hai, Liu Chi-Hung

Аннотация

OBJECTIVES: Whether established diagnostic criteria of carotid duplex ultrasonography (CDU) for atherosclerotic carotid artery stenosis are applicable to radiation vasculopathy in head and neck cancer (HNC) patients remains uncertain. This study aimed to validate the diagnostic accuracy of CDU for screening radiation-induced common carotid artery (CCA) stenosis.

METHODS: We enrolled 134 HNC patients with 268 carotid arteries, all of whom underwent CDU and computed tomographic angiography. Diameter stenosis and hemodynamic parameters were assessed on CDU, with ≥50% stenosis on computed tomographic angiography serving as the reference standard. Diagnostic performance was evaluated using sensitivity, specificity, PPV, NPV, and receiver operating characteristic (ROC) analysis to identify optimal cutoff values.

RESULTS: Using a B-mode cutoff of 50% to detect ≥50% CCA stenosis, the sensitivity, specificity, PPV, and NPV were 85.2, 88.1, 45.1, and 98.1%, respectively. The optimal B-mode threshold of 53%, which yielded a sensitivity of 75.9%, specificity of 91.4%, PPV of 51.2%, and NPV of 96.9%, with an area under the ROC curve (AUROC) of 0.894. In comparison, the optimal PSV threshold of 203 cm/s showed lower sensitivity (51.7%) but higher specificity (99.2%), with a PPV of 88.2%, NPV of 94.6%, and an AUROC of 0.698. Combining B-mode and PSV criteria resulted in an AUROC of 0.891, offering minimal incremental diagnostic benefit compared with B-mode assessment alone.

CONCLUSIONS: B-mode CDU may be a feasible screening tool for radiation-induced CCA stenosis. A B-mode threshold of 53% achieved diagnostic performance comparable to combined B-mode and velocity criteria for detecting ≥50% stenosis.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты