MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/jcma.0000000000000853

Медицинская библиотека · Journal of the Chinese Medical Association : JCMA · 2023

Freezing nitrogen ethanol composite reduces periprosthetic infection caused by Staphylococcus aureus contaminated metal implants: An animal study.

Chen Kuan-Lin, Chen Chao-Ming, Chen Yi-Chung, Wang Jir-You, Chen Cheng-Fong, Wu Po-Kuei, Chen Wei-Ming

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Implant-associated infection remains a major complication of orthopedic surgery. The treatment of such infection is complicated by bacterial biofilm formation on the metal surfaces of implants. Biofilm surrounds and protects the bacteria against the organism's endogenous defense system and from external agents such as antibiotics and mechanical debridement. This study aims to evaluate whether freezing nitrogen ethanol composite (FNEC), the combination of liquid nitrogen and 95% ethanol in a 3 to 1 ratio, used frequently in bone tumor surgery, is capable of disinfecting Staphylococcus aureus contaminated implants.

METHODS

The femurs of six New Zealand white rabbits were implanted with S. aureus-contaminated screws, half of which were treated with FNEC before implantation. The femurs were harvested 14 days after implantation. Histological analysis and TUNEL assay were conducted. The autoclaved screw, contaminated screw, and FNEC-treated contaminated screw were investigated using scanning electron microscopy to evaluate the biofilm structure.

RESULTS

The FNEC-treated group had significantly lower relative C-reactive protein levels. An obvious periosteal reaction at the implant site was observed in all rabbits in the non-FNEC group but none was observed in the FNEC-treated group. The FNEC-treated group exhibited fewer empty lacunae, less inflammatory infiltration, and less bone necrosis. Immunohistochemical analysis showed no S. aureus in bone tissue from the FNEC-treated group. Scanning electron microscopy showed disruption of the biofilm on the contaminated screw treated with FNEC.

CONCLUSION

FNEC showed potential in disinfecting S.aureus-contaminated implants. Further investigation is warranted, such as the effect on the implant-cement-bone interface, for FNEC to be used clinically in treating implant-associated infection.

Для цитирования: Chen Kuan-Lin, Chen Chao-Ming, Chen Yi-Chung, Wang Jir-You, Chen Cheng-Fong, Wu Po-Kuei, Chen Wei-Ming. Freezing nitrogen ethanol composite reduces periprosthetic infection caused by Staphylococcus aureus contaminated metal implants: An animal study.. Journal of the Chinese Medical Association : JCMA. 2023. DOI: 10.1097/jcma.0000000000000853.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.