Analysis of posterior deltoid function one year after surgical restoration of elbow extension.
Аннотация
PURPOSE: The purpose of this study was to measure the extent and timing of elbow extension torque recovery after posterior deltoid-to-triceps tendon transfer.
METHODS
Elbow extension moment was measured in 40 limbs from 23 patients who underwent surgical restoration using the posterior deltoid-to-triceps tendon transfer at times ranging from 8 weeks to 1 year after surgery. For comparison purposes, elbow extension moment also was measured in healthy controls and persons with C7 spinal cord injuries.
RESULTS
Maximum extension moment was 5.89 +/- 0.24 Nm (mean +/- standard error of mean, n = 40), which corresponds to approximately 65% of the predicted posterior deltoid force and provided an adequate moment to oppose gravity. Based on the shape of the moment-joint angle curve and using a biomechanical model, it was predicted that posterior deltoid was inserted at a relatively short muscle length of 123.1 mm and thus operated exclusively on the ascending limb of the length-tension relationship.
CONCLUSIONS
These observations support an evolving model of muscle architecture in which connective tissue septa restrict muscle fiber elongation during surgical tensioning of the tendon transfer. This relatively short length would result in a significant force loss should any of the repair sites slip or stretch during rehabilitation. These data have implications for the reconstruction and rehabilitation of this patient population.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.