DOI 10.1007/s00405-022-07587-1
Modified procedure for reconstructing the inferior wall of the orbit: identification of a reliable new landmark.
Аннотация
BACKGROUND
In orbital floor reconstruction, fractures involving the slope of the posterior end of the orbital floor make it difficult to determine the best location for implant placement. Therefore, landmarks for reconstruction are desirable to perform safe and reproducible reconstruction surgery.
METHODS
We developed a surgical procedure that focuses on three orbital landmarks: the infraorbital nerve, the inferior margin of the greater wing of the sphenoid bone, and the posterior superior wall of the maxilla.
CONCLUSIONS
Landmark-based orbital floor fracture reconstruction enables accurate reconstruction of fractures that extend to the slope of the posterior end of the orbital floor.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.