m+Medelevator.RU
← Поиск публикаций
AAPS PharmSciTech · 2026

Meloxicam Eluting 3D Printed 316L Stainless Steel Implants for Targeted Delivery in Bone Fixation Surgeries.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Annaji Manjusha, Poudel Ishwor, Mita Nur, Zhang Chu, Yeasmin Humaira, Lee Seungjong, Panizzi Peter, Arnold Robert D, Kaddoumi Amal, Shamsaei Nima, Farnum Byron, Fasina Oladiran, Babu R Jayachandra

Аннотация

Implant failures in orthopedic surgeries can occur due to inflammation, poor osteointegration, and biofilm formation. The local delivery of anti-inflammatory drugs is one of the potential solutions to address orthopedic implant failures caused by extensive inflammation, poor osteointegration, and biofilm formation. This study utilized a simple spray coating technique to deposit multilayer coatings of the anti-inflammatory drug meloxicam and PLGA on 3D printed 316L stainless steel implants. The implants were evaluated for their drug content, drug-polymer miscibility, static contact angle, corrosion resistance, in vitro release, cell adhesion, cell proliferation, and bacterial adhesion studies. The coatings aimed to improve osteointegration and reduce biofilm formation. The drug release studies demonstrated an initial burst release accompanied by sustained release for more than 30 days. The meloxicam-PLGA coated implants showed higher resistance to pitting corrosion, improved adhesion, and proliferation of human U2OS cells in comparison to uncoated implants. In addition, results from cell cytotoxicity studies confirmed that all the coatings are biocompatible and safe for in vivo application. The meloxicam-PLGA coated implants were also found to have significantly lower bacterial adhesion and biofilm formation compared to uncoated implants for both S. aureus (p < 0.01) and S. pseudintermedius (p < 0.01). The multilayer coatings developed in this study have the potential to improve adhesion at the implant-bone interface and thus might prevent implant rejections in patients undergoing orthopedic surgery. Moreover, this method can be applied to other drugs and polymers to address the issues related to implant failure, pain management, and surgical site infections.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты