Медицинская библиотека · African journal of paediatric surgery : AJPS · 2015
Repair of tracheo-oesophageal fistula secondary to button battery ingestion: A combined cervical and median sternotomy approach.
Клинический случайСтатьяПеревод в очереди
Аннотация
A three-year-old child developed a large tracheo-oesophageal fistula secondary to a button battery being lodged in the upper oesophagus for 36 hours. The diagnosis was confirmed with a contrast swallow. Operative access was gained through a combined right cervical incision and complete median sternotomy. Repair of the fistula required a segmental resection of both the trachea and oesophagus followed by primary anastomosis.
Для цитирования: Gopal Milan, Westgarth-Taylor Chris, Loveland Jerome. Repair of tracheo-oesophageal fistula secondary to button battery ingestion: A combined cervical and median sternotomy approach.. African journal of paediatric surgery : AJPS. 2015. DOI: 10.4103/0189-6725.151003.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.