MedElevator Войти в исследования
← Поиск публикаций

DOI 10.6061/clinics/2014(01)01

Медицинская библиотека · Clinics (Sao Paulo, Brazil) · 2014

Treatment of AO/OTA 31-A3 intertrochanteric femoral fractures with a percutaneous compression plate.

Luo Fei, Shen Jie, Xu Jianzhong, Dong Shiwu, Huang Qiang, Xie Zhao

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

AO/OTA 31-A3 intertrochanteric femoral fractures have completely different fracture line directions and biomechanical characteristics compared with other types of intertrochanteric fractures. The choice of the fixation method has been a focus of dispute among orthopedic trauma surgeons. The purpose of this study was to review the outcomes of these fractures treated with a percutaneous compression plate at our institute.

METHOD: Seventeen patients with AO/OTA 31-A3 intertrochanteric femoral fractures were treated with a percutaneous compression plate at our institute from January 2010 to December 2011. The clinical data and imaging results were retrospectively analyzed.

RESULTS

The medical complication of popliteal vein thrombosis occurred in one patient. Sixteen patients were followed up for 12 to 21 months. Two patients had malunion and mild pain. Fracture collapse occurred in two patients, with one having head penetration. These two patients had moderate pain. There were no occurrences of nonunion or reoperation. The mean Harris hip score obtained during the last follow-up was 84.1 (61-97). Patients with a poor quality of reduction were more likely to have pain results (p = 0.001). A trend existed toward the presence of a poor quality of reduction (p = 0.05) in patients with a collapse of fracture. Patients with poor preoperative mobility were more likely to have a lower Harris hip score (p = 0.000).

CONCLUSION

The percutaneous compression plate is an alternative device for the treatment of AO/OTA 31-A3 intertrochanteric femoral fractures. Good fracture reduction and an ideal placement position of the neck screw are important in the success of the device.

Для цитирования: Luo Fei, Shen Jie, Xu Jianzhong, Dong Shiwu, Huang Qiang, Xie Zhao. Treatment of AO/OTA 31-A3 intertrochanteric femoral fractures with a percutaneous compression plate.. Clinics (Sao Paulo, Brazil). 2014. DOI: 10.6061/clinics/2014(01)01.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.