Outcomes of biologic versus synthetic mesh in CDC class 3 and 4 open abdominal wall reconstruction.

Katzen Michael, Ayuso Sullivan A, Sacco Jana, Ku Dau, Scarola Gregory T, Kercher Kent W, Colavita Paul D, Augenstein Vedra A, Heniford B Todd

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

Abdominal wall reconstruction (AWR) in a contaminated field is associated with an increased risk of wound complications, infection, and reoperation. The best method of repair and mesh choice in these operations have generated marked controversy. Our aim was to compare outcomes of patients who underwent AWR with biologic versus synthetic mesh in CDC class 3 and 4 wounds.

METHODS

A prospective, single-institution database was queried for AWR using biologic or synthetic mesh in CDC Class 3 and 4 wounds. Hernia recurrence and complications were measured. Multivariable logistic regression was performed to identify factors predicting both.

RESULTS

In total, 386 patients with contaminated wounds underwent AWR, 335 with biologic and 51 with synthetic mesh. Groups were similar in age, sex, BMI, and rate of diabetes. Biologic mesh patients had larger hernia defects (298 ± 233cm2 vs. 208 ± 155cm2; p = 0.004) and a higher rate of recurrent hernias (72.2% vs 47.1%; p < 0.001), comorbidities(5.8 ± 2.7 vs. 4.2 ± 2.4, p < 0.01), and a nearly fivefold increase in Class 4 wounds (47.8% vs. 9.8%, p < 0.001), while fascial closure trended to being less common (90.7% vs 96.1%; p = 0.078). Hernia recurrence was comparable between biologic and synthetic mesh (10.4% vs. 17.6%, p = 0.132). Wound complication rates were similar (36.1% vs. 33.3%, p = 0.699), but synthetic mesh had higher rates of mesh infection (1.2% vs 11.8%; p < 0.001) and infection-related resection (0% vs 7.8%, p < 0.001), with 66% of those synthetic mesh infections requiring excision. On logistic regression, wound complications (OR 5.96 [CI 1.60-22.17]; p = 0.008) and bridging mesh (OR 13.10 [CI 2.71-63.42];p = 0.030) predicted of hernia recurrence (p < 0.05), while synthetic mesh (OR 18.6 [CI 2.35-260.4] p = 0.012) and wound complications (OR 20.6 [CI 3.15-417.7] p = 0.008) predicted mesh infection.

CONCLUSIONS

Wound complications in AWR with CDC class 3 and 4 wounds significantly increased mesh infection and hernia recurrence; failure to achieve fascial closure also increased hernia recurrence. Use of synthetic versus biologic mesh increased the mesh infection rate by 18.6 times.

Для цитирования: Katzen Michael, Ayuso Sullivan A, Sacco Jana, Ku Dau, Scarola Gregory T, Kercher Kent W, Colavita Paul D, Augenstein Vedra A, Heniford B Todd. Outcomes of biologic versus synthetic mesh in CDC class 3 and 4 open abdominal wall reconstruction.. Surgical endoscopy. 2022. DOI: 10.1007/s00464-022-09486-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.