MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0002-9378(99)70231-0

Медицинская библиотека · American journal of obstetrics and gynecology · 1999

The effect of amniotic fluid on the human omental artery in vitro.

Vedernikov Y P, Saade G R, Zlatnik M, Martin E, Garfield R E, Hankins G D

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The aim of the study was to determine the effect of amniotic fluid on the in vitro contractility of the human omental artery.

STUDY

DESIGN

Amniotic fluid and a segment of omentum were obtained from each of 5 patients at the time of planned cesarean delivery at normal term gestation for the indication of previous cesarean delivery. The omental artery was cleaned and cut into 3-mm rings, which were placed in 10-mL organ chambers for isometric tension recording. The chambers were filled with Krebs-Henseleit solution bubbled with 5% carbon dioxide in air and maintained at 37 C, pH 7.4. The rings were then equilibrated at 1 g passive tension for 90 minutes. The amniotic fluid was centrifuged for 10 minutes at 3000 rpm to remove all debris. Increasing volumes of supernatant (10-2000 microL) were added to the omental artery rings at baseline tone or after contraction with U46619 (10(-7) mol/L) or potassium chloride (60 mmol/L) to detect contractile and relaxant effects, respectively. Time-solvent control preparations were also run in parallel.

RESULTS

Amniotic fluid had no effect on the basal tone of omental artery rings. Amniotic fluid had no effect on the tension in rings previously contracted with either U46619 or potassium chloride.

CONCLUSIONS

Amniotic fluid has no direct effect on isolated human omental artery. The catastrophic hemodynamic changes associated with the syndrome of amniotic fluid embolism are not due to a direct effect of circulating amniotic fluid on vascular tone but rather may be due to secondary responses

Для цитирования: Vedernikov Y P, Saade G R, Zlatnik M, Martin E, Garfield R E, Hankins G D. The effect of amniotic fluid on the human omental artery in vitro.. American journal of obstetrics and gynecology. 1999. DOI: 10.1016/s0002-9378(99)70231-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.