DOI 10.1016/j.injury.2014.05.010
The primary determinants of radiation use during fixation of proximal femur fractures.
Аннотация
OBJECTIVES
To establish the primary determinants of operative radiation use during fixation of proximal femur fractures.
DESIGN
Retrospective cohort study.
SETTING
Level I trauma centre.
COHORT: 205 patients treated surgically for subtrochanteric and intertrochanteric femoral fractures.
MAIN OUTCOME MEASURES: Fluoroscopy time, dose-area-product (DAP).
RESULTS
Longer fluoroscopy time was correlated with higher body mass index (p=0.04), subtrochanteric fracture (p<0.001), attending surgeon (p=0.001), and implant type (p<0.001). Increased DAP was associated with higher body mass index (p<0.001), subtrochanteric fracture (p=0.002), attending surgeon (p=0.003), lateral body position (p<0.001), and implant type (p=0.05).
CONCLUSION
The strongest determinants of radiation use during surgical fixation of intertrochanteric and subtrochanteric femur fractures were location of fracture, patient body position, patient body mass index, and the use of cephalomedullary devices. Surgeon style, presumably as it relates to teaching efforts, seems to strongly influence radiation use.