BACKGROUND

Pelvic reconstruction after type I + II (or type I + II + III) internal hemipelvectomy with extensive ilium removal is a great challenge. In an attempt to anatomically reconstruct the hip rotation center (HRC) and achieve a low mechanical failure rate, a custom-made, 3D-printed prosthesis with a porous articular interface was developed. The aim of this study was to investigate the clinical outcomes of patients treated with this prosthesis.

METHODS

This retrospective cohort study included 28 patients with type I + II (+ III) internal hemipelvectomy through the articular interface of the sacroiliac joint and managed with a prosthesis at a single center between August 2016 and August 2021. Complications and oncological outcomes were analyzed. The position of the reconstructed HRC was assessed and lower-limb function was evaluated. Biomechanical analyses of different fixation modes of the prosthesis were conducted using finite element analysis.

RESULTS

The displacement distance of the HRC from preoperatively to postoperatively was a mean (and standard deviation) of 14.12 ± 8.75 mm. The rate of implant-related complications was 14.3% (4 of 28) for prosthetic breakage, 14.3% (4 of 28) for aseptic loosening, 7.1% (2 of 28) for dislocation, and 7.1% (2 of 28) for deep infection. The mean Musculoskeletal Tumor Society (MSTS)-93 score was 18.2. The aseptic loosening rate was significantly greater for prostheses fixed with 3 sacral screws (4 of 10, 40.0%) than for those fixed with 4 (0 of 10, 0%) or 5 screws (0 of 8, 0%) (p = 0.024). The prosthetic breakage rate was lower in patients who underwent lumbosacral fixation (0 of 13, 0%) than in those who did not (4 of 15, 26.7%), although the difference did not reach significance (p = 0.102). Biomechanical analyses suggested that the addition of lumbosacral fixation or increasing the number of sacral screws from 3 to 4 or 5 visibly reduced the peak stress of the sacral screws.

CONCLUSIONS

The use of a 3D-printed prosthesis with an articular interface for pelvic reconstruction demonstrated stable prosthetic fixation, anatomical acetabular reconstruction, and acceptable early functional outcomes.

LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Huang Xin, Huang Donghua, Lin Nong, Yan Xiaobo, Qu Hao, Ye Zhaoming. 3D-Printed Prosthesis with an Articular Interface for Anatomical Acetabular Reconstruction After Type I + II (+ III) Internal Hemipelvectomy: Clinical Outcomes and Finite Element Analysis.. The Journal of bone and joint surgery. American volume. 2024. DOI: 10.2106/jbjs.23.01462.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.