MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-020-03370-7

Медицинская библиотека · BMC musculoskeletal disorders · 2020

Three-dimensional printing of patient-specific plates for the treatment of acetabular fractures involving quadrilateral plate disruption.

Wang Canbin, Chen Yuhui, Wang Liping, Wang Di, Gu Cheng, Lin Xuezhi, Liu Han, Chen Jiahui, Wen Xiangyuan, Liu Yuancheng, Huang Fuming, Yao Lufeng, Fan Shicai, Huang Wenhua, Dong Jianghui

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Complicated acetabular fractures comprise the most challenging field for orthopedists. The purpose of this study was to develop three-dimensional printed patient-specific (3DPPS) Ti-6Al-4 V plates to treat complicated acetabular fractures involving quadrilateral plate (QLP) disruption and to evaluate their efficacy.

METHODS

Fifty patients with acetabular fractures involving QLP disruption were selected between January 2016 and June 2017. Patients were divided into a control group (Group A, 35 patients) and an experimental group (Group B, 15 patients), and were treated by the conventional method of shaping reconstruction plates or with 3DPPS Ti-6AL-4 V plates, respectively. The efficacy of Ti-6AL-4 V plates was evaluated by blood loss, operative time, reduction quality, postoperative residual displacement, and complications.

RESULTS

The operative time and blood loss in Group B were reduced compared to Group A, and the difference was statistically significant (P < 0.05). There was no significant difference in reduction quality between the two groups (P > 0.05). Reduction quality in Group B was anatomic in 10 (66.7%), satisfactory in four (26.7%), and poor in one (6.7%). In Group A, they were anatomic in 18 (51.4%), satisfactory in 13 (37.1%), and poor in four (11.4%). Residual displacement in Group B was less than that in Group A, and the difference was statistically significant (P < 0.05). In Group B, one case exhibited loosening of the pubic screw postoperatively. In Group A, there was one case of wound infection, one of deep vein thrombosis (DVT) in the ipsilateral lower limb, one case of traumatic arthritis and two obturator nerve injuries.

CONCLUSIONS

The 3DPPS Ti-6AL-4 V plate is a feasible, accurate and effective implant for acetabular fracture treatment.

Для цитирования: Wang Canbin, Chen Yuhui, Wang Liping, Wang Di, Gu Cheng, Lin Xuezhi, Liu Han, Chen Jiahui, Wen Xiangyuan, Liu Yuancheng, Huang Fuming, Yao Lufeng, Fan Shicai, Huang Wenhua, Dong Jianghui. Three-dimensional printing of patient-specific plates for the treatment of acetabular fractures involving quadrilateral plate disruption.. BMC musculoskeletal disorders. 2020. DOI: 10.1186/s12891-020-03370-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.