MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijoa.2021.103195

Медицинская библиотека · International journal of obstetric anesthesia · 2021

Fetal heart rate monitoring during fetoscopic repair of open spinal neural tube defects: a single-centre observational cohort study.

García I, Suárez E, Maiz N, Pascual M, Perera R, Arévalo S, Giné C, Molino J A, López M, Carreras E, Manrique S

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

During fetal surgery, the haemodynamic stability of the fetus depends on the haemodynamic stability of the mother. The primary objective of this study was to assess changes in fetal heart rate (FHR) throughout the different stages of surgery. The secondary objective was to assess potential changes in maternal physiological parameters and their association with FHR.

METHODS

This was a single-center observational cohort study conducted between 2015 and 2019 in 26 women undergoing intra-uterine fetoscopic repair of open spina bifida. The primary outcome was FHR. Maternal physiologic parameters were measured at the beginning, during and after surgery. The linear mixed-effects model fitted by maximum likelihood was used to assess changes in each variable at specific times throughout the surgery, and the repeated measures correlation coefficient was used to study the association between FHR and maternal physiological parameters.

RESULTS

One (3.8%) case of fetal bradycardia (FHR <110 beats per minute) required the administration of intramuscular atropine. No other significant FHR changes were observed during surgery. Maternal oesophageal temperature (P <0.001), lactate levels (P=0.002), and mean arterial pressure (P=0.016) changed significantly during surgery, although none of these changes was clinically relevant. The FHR showed a significant association with maternal carbon dioxide tension (r=0.285, 95% CI 0.001 to 0.526) and maternal heart rate (r=0.302, 95% CI 0.025 to 0.535).

CONCLUSION

The FHR remained stable during intra-uterine fetoscopic repair of open spina bifida. Maternal carbon dioxide tension and heart rate may have a mild influence on FHR.

Для цитирования: García I, Suárez E, Maiz N, Pascual M, Perera R, Arévalo S, Giné C, Molino J A, López M, Carreras E, Manrique S. Fetal heart rate monitoring during fetoscopic repair of open spinal neural tube defects: a single-centre observational cohort study.. International journal of obstetric anesthesia. 2021. DOI: 10.1016/j.ijoa.2021.103195.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.