MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/brs.0b013e318193a21b

Медицинская библиотека · Spine · 2009

C1 pedicle screws versus C1 lateral mass screws: comparisons of pullout strengths and biomechanical stabilities.

Ma Xiang-Yang, Yin Qing-Shui, Wu Zeng-Hui, Xia Hong, Liu Jing-Fa, Xiang Ming, Zhao Wei-Dong, Zhong Shi-Zhen

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

DESIGN

In vitro biomechanical study.

OBJECTIVE

To compare the pullout strengths and the biomechanical stabilities afforded by C1 lateral mass screws and C1 pedicle screws using bicortical and unicortical fixation techniques.

SUMMARY OF BACKGROUND DATA: Posterior screw fixation techniques in the atlas including C1 lateral mass screw and C1 pedicle screw. The shortcomings of C1 lateral mass screw technique and potential risks of bicortical fixation method were recently described; C1 pedicle screw technique with unicortical fixation might overcome these anatomic and clinical drawbacks. However, it is unknown whether the biomechanical characteristics of unicortical C1 pedicle screw are comparable with that of bicortical C1 lateral mass screw. METHODS.: Bicortical or unicortical C1 pedicle screws and C1 lateral mass screws were inserted into 12 adult fresh human C1 specimens. Pullout strength was evaluated using a material testing machine. The construct's stability of bicortical C1 lateral mass screws or unicortical C1 pedicle screws incorporating unicortical C2 pedicle screws was compared with bilateral transarticular screws using another 6 fresh cervical cadaver spines. Pullout strength and biomechanical stability differences were compared statistically.

RESULTS

Bicortical C1 pedicle screws provided the biggest pullout strength (1757.0 +/- 318.7 N) of all 4 methods, whereas unicortical C1 lateral mass screws provided the weakest(794.5 +/- 314.8 N). However, there were no statistically significant differences between bicortical C1 lateral mass screws (1243.8 +/- 350.0 N) and unicortical C1 pedicle screws (1192.5 +/- 172.6 N). Furthermore, there was no statistically significant difference of biomechanical construct stability between unicortical C1 pedicle screw-rod constructs and bicortical C1 lateral mass screw-rod constructs.

CONCLUSION

C1 pedicle screws are stiffer than C1 lateral mass screws. Unicortical C1 pedicle screw provided the same pullout resistance and three-dimensional stability as bicortical C1 lateral mass fixation. Although lateral mass screw placement into C1 requires bicortical purchase, pedicle screw insertion into the atlas only requires unicortical fixation.

Для цитирования: Ma Xiang-Yang, Yin Qing-Shui, Wu Zeng-Hui, Xia Hong, Liu Jing-Fa, Xiang Ming, Zhao Wei-Dong, Zhong Shi-Zhen. C1 pedicle screws versus C1 lateral mass screws: comparisons of pullout strengths and biomechanical stabilities.. Spine. 2009. DOI: 10.1097/brs.0b013e318193a21b.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.