DOI 10.1016/j.toxicon.2020.09.005
Saxitoxin aptasensor based on attenuated internal reflection ellipsometry for seafood.
Аннотация
In this study, we proposed label-free saxitoxin (STX) sensor using STX specific aptamer in combination with spectroscopic ellipsometry (SE) and attenuated internal reflection (AIR) spectroscopic ellipsometry method which is operated under surface plasmon resonance (SPR) conditions. Besides the other surface plasmon resonance-based applications, AIR-SE applications have unique advantages in terms of sensitivity and it was used herein for real-time detection of STX in real samples. Another method, SE, was also used and compared with AIR-SE. Analytical performances were satisfactory with low detection limits and a wide detection range. Limit of detection was 0.01 ng/mL for AIR-SE and 0.11 ng/mL for SE. Both proposed sensors were operable in 0.01 nM-1000 nM STX range. These methods were also used for the accurate, selective, and sensitive detection of STX from fish and shrimp samples.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.