DOI 10.1016/j.tjog.2022.02.049
Comparison of two outside-in transobturator midurethral slings in the treatment of female urodynamic stress incontinence.
Аннотация
OBJECTIVE
To explore the difference between two brands of outside-in transobturator midurethral sling (TOT) for urodynamic stress incontinence (USI).
MATERIALS AND
METHODS
Women who underwent an outside-in TOT procedure by either Monarc or Obtryx were retrospectively reviewed. Data of women with available information at baseline and postoperative 12-month follow-up were analyzed. The analyzed data included standardized interview, pelvic examination, as well as sling location and sling tension explored by introital four-dimensional ultrasound. Sling position were explored through the distances between the sling center and the caudal margin of the pubic symphysis (SPd) as well as sling percentile (SP) along the urethral length as a percentage in the midsagittal plane. SPd was also used to explore sling tension. Clinical outcomes were compared between two groups. Sling location and sling tension were compared in success cases between two groups.
RESULTS
There were 138 women in Monarc group and 140 women in Obtryx group. Rates of stress urinary continence and adverse events were not statistically different after two TOT. SPd was similar between both procedures. Obtryx located more ventrally than Monarc, indicated by a smaller SP during resting (41.6% vs 58.5%, P < 0.001), straining (38.0% vs 54.4%, P < 0.001), and coughing (39.8% vs 48.8%, P < 0.001).
CONCLUSION
At 12-month assessment, both outside-in TOT procedures were not significantly different in terms of clinical results and sling tension, while Obtryx sling located more ventrally than Monarc.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.