Choo Younwoo, Kim Jooyoung, Cho Jun-Sik, Kim Sorin, Kim Hwi-Yool
Аннотация
OBJECTIVE: To compare the maximum failure load and failure mode among 3 fixation methods for canine olecranon fractures and evaluate the feasibility of replacing the pin and tension band wiring method with screw plus tension band wiring (TBW) methods.
METHODS: 18 ulnas from 9 canine cadavers (10.3 to 16.4 kg) were collected and randomly assigned to 3 groups (n = 6) for surgical procedures. Surgical procedures and biomechanical testing were performed from June 14 through October 7, 2024. A transverse ulnar osteotomy was performed immediately proximal to the anconeal process and aligned perpendicularly to the caudal cortex. In group 1, the pin and tension band wiring technique was employed using 2 1.2-mm Kirschner wires and #2 FiberWire. Group 2 applied the screw TBW method using a partially threaded cannulated screw and #2 FiberWire. Group 3 used the screw TBW method but with a fully threaded headless cannulated screw and #2 FiberWire. Biomechanical testing was conducted to apply tensile forces using a universal testing machine.
RESULTS: Maximum failure loads of groups 1 (n = 6), 2 (n = 6), and 3 (n = 6) were 351.3 ± 22.2 N, 345.78 ± 25.6 N, and 326.3 ± 18.2 N, respectively. No significant difference was observed in maximum failure loads among the groups.
CONCLUSIONS: This study suggests that the screw with TBW methods represent viable alternatives for internal fixation in extra-articular transverse olecranon fractures in dogs.
CLINICAL RELEVANCE: This study's results imply that fully threaded headless cannulated screws can be effectively applied to areas under tensile forces.
METHODS: 18 ulnas from 9 canine cadavers (10.3 to 16.4 kg) were collected and randomly assigned to 3 groups (n = 6) for surgical procedures. Surgical procedures and biomechanical testing were performed from June 14 through October 7, 2024. A transverse ulnar osteotomy was performed immediately proximal to the anconeal process and aligned perpendicularly to the caudal cortex. In group 1, the pin and tension band wiring technique was employed using 2 1.2-mm Kirschner wires and #2 FiberWire. Group 2 applied the screw TBW method using a partially threaded cannulated screw and #2 FiberWire. Group 3 used the screw TBW method but with a fully threaded headless cannulated screw and #2 FiberWire. Biomechanical testing was conducted to apply tensile forces using a universal testing machine.
RESULTS: Maximum failure loads of groups 1 (n = 6), 2 (n = 6), and 3 (n = 6) were 351.3 ± 22.2 N, 345.78 ± 25.6 N, and 326.3 ± 18.2 N, respectively. No significant difference was observed in maximum failure loads among the groups.
CONCLUSIONS: This study suggests that the screw with TBW methods represent viable alternatives for internal fixation in extra-articular transverse olecranon fractures in dogs.
CLINICAL RELEVANCE: This study's results imply that fully threaded headless cannulated screws can be effectively applied to areas under tensile forces.