STUDY

OBJECTIVE

To establish a porcine uterine horn adhesion model that mimicked laparoscopic procedures and use it to investigate the effect of a spray-type, novel dextrin hydrogel adhesion barrier (AdSpray; Terumo Corporation, Tokyo, Japan) on postsurgical adhesions.

DESIGN

A single-blind randomized controlled trial (Canadian Task Force Classification I).

SETTING

A Certified animal research facility.

SUBJECTS: Sixteen female pigs.

INTERVENTIONS: All animals underwent laparoscopically assisted adhesion-inducing surgery. The uterine horns and the peritoneum of the pelvic sidewall were injured. In the experimental group, AdSpray was applied to the injured site, and the handling of the sprayer was assessed. At 28 ± 1 days after surgery, animals were sacrificed, and adhesions at the injured site were evaluated. Uterine horn suture sites were examined under a light microscope to assess healing of the incised wound, the inflammatory reaction, abscess, and the foreign body reaction to the surgical suture.

MEASUREMENTS AND MAIN

RESULTS

The control group showed severe adhesions over the entire surface interface at the uterine horn suture sites and peritoneal resection site. Compared with the control treatment, AdSpray exhibited a higher percentage of adhesion-free sites (p < .001) and reduced the total adhesion score (p < .001). In the AdSpray group, no inflammation or abscess formation was observed on histopathological examination, and ideal healing of the suture sites was confirmed in all cases.

CONCLUSION

Based on the results of the present study, the novel dextrin hydrogel shows excellent adhesion prevention and can be easily applied during laparoscopy using a dedicated sprayer.

Для цитирования: Kai Miho, Maeda Kazuha, Tasaki Masako, Kira Shinichiro, Nakamura Shintaro, Chino Naotaka, Hagiwara Hitomi, Nishida Hitoshi, Kawanishi Tetsuro. Evaluation of a Spray-type, Novel Dextrin Hydrogel Adhesion Barrier Under Laparoscopic Conditions in a Porcine Uterine Horn Adhesion Model.. Journal of minimally invasive gynecology. 2017. DOI: 10.1016/j.jmig.2017.09.023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.