DOI 10.1016/j.ccrj.2026.100166
Venoarterial extracorporeal membrane oxygenation (VA-ECMO) in high-risk (HR) percutaneous coronary intervention (PCI).
Аннотация
OBJECTIVE
Mechanical circulatory support is increasingly utilised in peri-procedural contexts. Herein we describe the characteristics and outcomes of patients undergoing high-risk (HR) percutaneous coronary intervention (PCI) with venoarterial extracorporeal membrane oxygenation (VA-ECMO) support.
DESIGN
Single centre, retrospective cohort study conducted at a quaternary Australian ECMO retrieval hospital.
METHODS
Consecutive patients between January 2019 and June 2024, who received peripheral VA-ECMO support for HR-PCI were identified from the institutional ECMO database. The primary outcome was the incidence of major adverse cardiovascular and cerebrovascular events (MACCE) to hospital discharge. Secondary endpoints included procedural success, incidence of vascular access and bleeding complications, acute kidney injury (AKI), and duration of mechanical circulatory support (MCS), ventilation, ICU and hospital length of stay.
RESULTS
Seventeen patients received VA-ECMO supported HR-PCI during the study period. The median age was 70 years (IQR; 59-78). Fourteen (82 %) patients were male; fifteen (88 %) had moderate to severe left ventricular dysfunction pre-procedurally. Ten (59 %) patients underwent emergency VA-ECMO support and seven (41 %) patients were supported prophylactically, with mean pre-procedural SYNTAX scores of 39 ± 12 and 30 ± 10, respectively. Seven MACCE events occurred, all being death in the emergency group. Fifteen patients (88 %) were successfully revascularised. Significantly more patients in the emergency versus the prophylactic group developed AKI (80 % vs 14 %, p = 0.02). There were significantly more vascular and access-related complications in the emergency group (7 vs 1, p = 0.049).
CONCLUSION
In seventeen patients undergoing HR-PCI, prophylactic VA-ECMO support was feasible, safe and associated with good short-term outcomes, whilst emergency VA-ECMO supported HR-PCI was associated with greater burden of mortality and morbidity. Larger prospective studies, including cost analysis comparing other MCS devices are required.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.