MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-019-3021-2

Медицинская библиотека · BMC musculoskeletal disorders · 2019

Navigation-assisted suture anchor insertion for arthroscopic rotator cuff repair.

Micic Ivan, Kholinne Erica, Hong Hanpyo, Choi Hyunseok, Kwak Jae-Man, Sun Yucheng, Hong Jaesung, Koh Kyoung-Hwan, Jeon In-Ho

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Suture anchor placement for subscapularis repair is challenging. Determining the exact location and optimum angle relative to the subscapularis tendon direction is difficult because of the mismatch between a distorted arthroscopic view and the actual anatomy of the footprint. This study aimed to compare the reliability and reproducibility of the navigation-assisted anchoring technique with conventional arthroscopic anchor fixation.

METHODS

Arthroscopic shoulder models were tested by five surgeons. The conventional and navigation-assisted methods of suture anchoring in the subscapularis footprint on the humeral head were tested by each surgeon seven times. Angular results and anchor locations were measured and compared using the Wilcoxon signed rank test. Interobserver intraclass correlation coefficients (ICCs) were analyzed among the surgeons.

RESULTS

The mean angular errors of the targeted anchor fixation guide without and with navigation were 17° and 2° (p < 0.05), respectively, and the translational errors were 15 and 3 mm (p < 0.05), respectively. All participants showed a narrow range of anchor fixation angular and translational errors from the original target. Among the surgeons, the interobserver reliabilities of angular errors for ICCs of the navigation-assisted and conventional methods were 0.897 and 0.586, respectively, and the interobserver ICC reliabilities for translational error were 0.938 and 0.619, respectively.

CONCLUSIONS

The navigation system may help surgeons be more aware of the surrounding anatomy and location, providing better guidance for anchor orientation, including footprint location and anchor angle.

Для цитирования: Micic Ivan, Kholinne Erica, Hong Hanpyo, Choi Hyunseok, Kwak Jae-Man, Sun Yucheng, Hong Jaesung, Koh Kyoung-Hwan, Jeon In-Ho. Navigation-assisted suture anchor insertion for arthroscopic rotator cuff repair.. BMC musculoskeletal disorders. 2019. DOI: 10.1186/s12891-019-3021-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.