MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jaapos.2009.12.161

Медицинская библиотека · Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus · 2010

Ocular findings of oral sildenafil use in term and near-term neonates.

Kehat Rinat, Bonsall Dean J, North Robert, Connors Brenda

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Sildenafil is a phosphodiesterase type 5 inhibitor used as a therapeutic adjunct in critically ill neonates with persistent pulmonary hypertension. Sildenafil is associated with several ocular complications in adults and is suspected to exacerbate retinopathy of prematurity (ROP). The risk of ocular complication in sildenafil-treated newborns, not otherwise at risk for the development of ROP, is unknown.

METHODS

Twenty-two neonates with birth gestational age greater than 34 weeks and birth weight over 2,100 g who received oral sildenafil for more than 2 weeks were assessed by a pediatric ophthalmologist for potential ocular complications.

RESULTS

Four patients had ocular findings: 2 had bacterial conjunctivitis; 1 had optic nerve hypoplasia, choroidal coloboma, and nystagmus; 1 had previously suffered from a hypotensive episode and had a documented cortical injury accompanied by bilateral optic disk atrophy and nystagmus. All cases seemed unrelated to sildenafil use and improved despite continued use of the drug.

CONCLUSIONS

Our results do not support the need for a routine ophthalmologic examination in term and near-term neonates receiving sildenafil.

Для цитирования: Kehat Rinat, Bonsall Dean J, North Robert, Connors Brenda. Ocular findings of oral sildenafil use in term and near-term neonates.. Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus. 2010. DOI: 10.1016/j.jaapos.2009.12.161.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.