Electrophysiologic analysis of injury to cranial nerve XI during neck dissection.

Lanisnik Bostjan, Zargi Miha, Rodi Zoran

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Despite preservation of the accessory nerve, a considerable number of patients report partial nerve damage after modified radical neck dissection (MRND) and selective neck dissection.

METHODS

Accessory nerve branches for the trapezius muscle were stimulated during neck dissection, and the M wave amplitude was measured during distinct surgical phases.

RESULTS

The accessory nerve was mapped in 20 patients. The M wave recordings indicated that major nerve damage occurred during dissection at levels IIa and IIb in the most proximal segment of the nerve. The M waves evoked from this nerve segment decreased significantly during surgery (analysis of variance; p = .001).

CONCLUSION

The most significant intraoperative injury to the accessory nerve during neck dissection occurs at anatomic nerve levels IIa and IIb. © 2015 Wiley Periodicals, Inc. Head Neck 38: E372-E376, 2016.

Для цитирования: Lanisnik Bostjan, Zargi Miha, Rodi Zoran. Electrophysiologic analysis of injury to cranial nerve XI during neck dissection.. Head & neck. 2015. DOI: 10.1002/hed.24002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.