MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ansa.70050

Медицинская библиотека · Analytical science advances · 2025

Development and Optimization of a Dispersive Liquid-Liquid Microextraction Method for the Simultaneous Determination of Multiclass Pesticides in Environmental Waters.

Negussie Bezuayehu Tadesse, Dube Simiso, Muzi Nindi Mathew, Tesfaw Asmamaw

СтатьяПеревод в очереди

Аннотация

The widespread use of pesticides in modern agriculture necessitates sensitive and sustainable methods to monitor their residues in environmental waters. This study reports the development and optimization of a dispersive liquid-liquid microextraction (DLLME) method combined with high performance liquid chromatography with diode array detector (HPLC-DAD) for the simultaneous determination of multiclass pesticides (metalaxyl, benalaxyl, chlorpyrifos, endrin, 4,4'-DDT and bifenthrin). Key extraction variables-including the type and volume of extraction/disperser solvents, pH, salt addition and vortex speed/time-were systematically evaluated. The optimized method employed tetrachloroethylene as the extraction solvent, acetonitrile as the disperser, pH 7, 3% w/v NaCl, a vortex speed of 1200 rpm and an extraction time of 80 s. Under these conditions, excellent enrichment factors, recoveries (87%-108%) and precision (intradays: 2.8%-8.6%; interday: 4.2%-8.6%) were achieved. The correlation coefficients (r 2) exceeded 0.9977, and the limits of detection ranged from 0.3 to 1.3 µg/L. Compared to conventional extraction techniques, the proposed DLLME method provides faster analysis and uses less solvent. This approach provides a robust, sensitive and environmentally friendly alternative for monitoring multiclass pesticide residues in diverse water matrices.

Для цитирования: Negussie Bezuayehu Tadesse, Dube Simiso, Muzi Nindi Mathew, Tesfaw Asmamaw. Development and Optimization of a Dispersive Liquid-Liquid Microextraction Method for the Simultaneous Determination of Multiclass Pesticides in Environmental Waters.. Analytical science advances. 2025. DOI: 10.1002/ansa.70050.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.