MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fped.2025.1555539

Медицинская библиотека · Frontiers in pediatrics · 2025

Key ultrasound predictors in the prenatal assessment of congenital pulmonary airway malformation: a single-center experience.

Fabietti Isabella, Novak Alice, Valfrè Laura, Vassallo Chiara, De Rose Domenico Umberto, Viggiano Milena, Conforti Andrea, Iacusso Chiara, Bonito Marco, Bagolan Pietro, Caforio Leonardo

СтатьяПеревод в очереди

Аннотация

BACKGROUND

This study assesses the sensitivity and specificity of congenital pulmonary airway malformation (CPAM) Volume Ratio (CVR) in predicting the need for fetal therapy (FT) and explores the role of additional ultrasound indicators, including the Observed/Expected Lung to Head Ratio (O/E LHR) and Mediastinal Angle Shift (MSA), in improving FT prediction.

METHODS

We retrospectively studied all CPAM cases referred to our Center from 2018 to 2022. FT was provided at any CVR value in cases of hydrops, rapid lesion growth, or polyhydramnios. The worst CVR, O/E LHR, and MSA values between 20 and 28 weeks of gestation were analyzed.

RESULTS

Among 62 CPAM cases, 56.4% right-sided and 43.5% left-sided. Hydrops occurred in 5 cases, all right-sided. FT was required in 14 cases (11 receiving steroids and 3 thoraco-amniotic shunt). CVR was significantly higher in the FT group compared to the non-FT group (p < 0.0001), with an optimal cut-off of 1.25 (Sn 100%; Sp 89.6%) for predicting FT. The O/E LHR was significantly lower in the FT group (mean 44.8 vs. 58.3; p = 0.0046, AUC 0.75), with a Sn of 84% and Sp of 62%. MSA was significantly higher in the FT compared to the non-FT group (p < 0.0001), with a threshold of 13.3° providing high Sn (92.8%) and Sp (89.3%) for predicting FT.

CONCLUSIONS

CVR is the most reliable predictor of the need for FT, even at lower thresholds. MSA can effectively complement CVR in predicting FT, and using multiple parameters may improve parental counseling and identify cases needing closer monitoring.

Для цитирования: Fabietti Isabella, Novak Alice, Valfrè Laura, Vassallo Chiara, De Rose Domenico Umberto, Viggiano Milena, Conforti Andrea, Iacusso Chiara, Bonito Marco, Bagolan Pietro, Caforio Leonardo. Key ultrasound predictors in the prenatal assessment of congenital pulmonary airway malformation: a single-center experience.. Frontiers in pediatrics. 2025. DOI: 10.3389/fped.2025.1555539.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.