MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00192-025-06364-y

Медицинская библиотека · International urogynecology journal · 2025

Effectiveness of Perineal Protection Devices in Reducing Birth-Related Perineal Trauma: A Systematic Review and Meta-Analysis of Randomized Controlled Trials and GRADE Assessment.

Allam Salma, Abdelkader Omar Khalid Samir, Mansour Rana, Elsayed Nour, Elshiekh Hind, Tarabishi Joudi, Hegazy Sara Mohammad, Arafa Amr, Kertam Ahmed

СтатьяСистематический обзорМетаанализПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Perineal trauma during childbirth is a common complication with significant short- and long-term maternal consequences. Perineal protection devices (PPDs) have been developed as a potential preventive strategy, yet their clinical effectiveness remains under evaluation.

AIM: To assess the effectiveness of perineal protection devices in reducing the incidence and severity of birth-related perineal trauma.

METHODS

A systematic review and meta-analysis of randomized controlled trials (RCTs) was conducted. Eligible studies were identified from PubMed, Scopus, Web of Science, and Embase. Primary outcomes included rates of intact perineum, perineal tears (grade ≥ 2), labial tears, episiotomy, and Apgar scores. Secondary outcomes included adverse effects and feasibility. The Cochrane Risk of Bias tool 2 and GRADE assessment were used to evaluate study quality.

RESULTS

Five RCTs involving 2331 participants were included. PPD use was associated with a significantly increased rate of intact perineum (RR 1.41; 95% CI 1.18-1.69; p < 0.001). No significant differences were found for grade 1 (RR 1.05; p = 0.48), grade 2 (RR 0.92; p = 0.32), or grade 3-4 perineal tears (RR 0.76; p = 0.26). Labial tears showed no significant reduction overall (RR 0.90; p = 0.64), but sensitivity analysis revealed a benefit after excluding one study (RR 0.72; p = 0.02). No significant differences were found in episiotomy rates (RR 0.96; p = 0.62) or Apgar scores < 7 at 5 min (RR 0.99; p = 0.93).

CONCLUSION

PPDs appear safe and effective in increasing intact perineum rates without adverse neonatal outcomes. Further large-scale, standardized trials are needed to confirm their role in obstetric practice.

Для цитирования: Allam Salma, Abdelkader Omar Khalid Samir, Mansour Rana, Elsayed Nour, Elshiekh Hind, Tarabishi Joudi, Hegazy Sara Mohammad, Arafa Amr, Kertam Ahmed. Effectiveness of Perineal Protection Devices in Reducing Birth-Related Perineal Trauma: A Systematic Review and Meta-Analysis of Randomized Controlled Trials and GRADE Assessment.. International urogynecology journal. 2025. DOI: 10.1007/s00192-025-06364-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.