BACKGROUND

Disseminated intravascular coagulopathy (DIC) is a rare symptom complex that causes embolisms within the microvasculature and extensive necrosis of the skin and the acres. During surgical decision-making, preserving functionally important structures must be weighed against radical debridement. The aim was to analyze functional recovery and quality of life of patients sustaining amputations from disseminated intravascular coagulopathy and supplied with bionic prostheses.

METHODS

A monocentric, retrospective review of patients with disseminated intravascular coagulopathy after sepsis was conducted from 2016 to 2018. After initial reconstruction and intensive care treatment, patients were provided with bionic prosthetic devices. A follow-up survey measuring function and quality of life was performed.

RESULTS

Three patients (mean: 45 years; median: 50 years) were analyzed. The first necrectomy and amputation were performed, on average, after >4 weeks post-symptom onset. All patients required re-amputation, averaging two or one re-amputations in the right or left upper extremity, respectively, and one in ​​the lower extremities. On average, 12 operations for reconstruction of skin defects were required (x͂=8). On average, patients tolerated their prostheses for 5.67 h per day. Satisfaction metrics were either sufficient (SF-36, x̅=69) or moderate (TAPES-R, x̅=4.7). Physical skills were rated poor to fair (average TAPES-R=2.67).

CONCLUSION

Supplying bionic prostheses after DIC yielded sufficient to moderate results. However, prothesis weight, signal transmission disorders, and repeated functional failures were suboptimal. For extensive stump scarring, implantable signal electrodes may improve signal transmission.

Для цитирования: Werner Dennis, Alawi Seyed Arash. Four Extremity Amputation and Bionic Prosthesis Supply after Disseminated Intravascular Coagulation: A Follow-Up on Functionality and Quality of Life after Bionic Prosthesis Supply.. World journal of plastic surgery. 2019. DOI: 10.29252/wjps.8.2.146.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.