Clinical biomechanics (Bristol, Avon) · 2021

In vivo measurement of distance between scapular neck and polyethylene insert during active external rotation in shoulders with Grammont type reverse prosthesis.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Matsuki Keisuke, Matsuki Kei O, Sugaya Hiroyuki, Takahashi Norimasa, Tokai Morihito, Ueda Yusuke, Hoshika Shota, Hamada Hiroshige, Banks Scott A

Аннотация

BACKGROUND: Scapular notching is a frequently observed complication after reverse shoulder arthroplasty. Impingement of the humeral plastic insert against the scapular neck is believed to be the cause of notching. There have been no in vivo studies that analyzed the positional relationship between the scapular neck and humeral insert. The purpose of this study was to measure the distance between the scapular neck and insert in shoulders with Grammont-type prostheses during active external rotation at the side.

METHODS: Eighteen shoulders with Grammont-type prostheses were enrolled in this study. There were 13 males and 5 females, and the mean age at surgery was 74 years (range, 63-91). Fluoroscopic images were recorded during active external rotation at the side from maximum internal to external rotation at an average of 14 months (range, 7-24) after surgery. Implant kinematics were determined with three-dimensional models of the implants and fluoroscopic images using model-image registration techniques. Based on the implant kinematics, the closest distance between the scapular neck and insert was computed at each 5° increment of glenohumeral internal/external rotation.

RESULTS: Mean glenohumeral abduction during rotation was 17°-22°. The mean distance between the neck and insert was approximately 1 mm throughout the activity. The separation distance tended to narrow with arm external rotation, but the change was not significant.

INTERPRETATION: The small distance between the scapular neck and insert in early post-operative reverse shoulder arthroplasty patients may be associated with the high incidence of scapular notching in Grammont-type prostheses.