Dynamic hip screw compared with external fixation for treatment of osteoporotic pertrochanteric fractures. A prospective, randomized study.

Moroni Antonio, Faldini Cesare, Pegreffi Francesco, Hoang-Kim Amy, Vannini Francesca, Giannini Sandro

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Although the use of a sliding hip screw is considered to be the preferred treatment for pertrochanteric femoral fractures, we theorized that external fixation could produce clinical outcomes equal to, if not better than, the outcomes obtained with conventional treatment. Furthermore, because external fixation is minimally invasive, we expected a lower rate of morbidity and a reduced need for blood transfusions. Therefore, we compared the two treatments in a clinical trial of elderly patients with pertrochanteric fracture.

METHODS

Forty consecutive elderly female patients who had a pertrochanteric fracture were randomized to be treated with either fixation with a 135 degrees four-hole sliding hip screw (Group A) or an external fixation device with hydroxyapatite-coated pins (Group B). The inclusion criteria were female gender, an age of at least sixty-five years, an AO/OTA type-A1 or A2 fracture, and a bone mineral density T-score of less than -2.5. There were no differences in patient age, fracture type, bone mineral density, comorbidities, length of hospital stay, or quality of reduction between the two groups.

RESULTS

The average intraoperative time (and standard deviation) was 64 +/- 6 minutes in Group A and 34 +/- 5 minutes in Group B (p < 0.005). The average number of units of blood transfused postoperatively was 2.0 +/- 0.1 in Group A and none in Group B (p < 0.0001). Group B had less pain five days postoperatively (p < 0.05). Varus collapse of the fracture at six months averaged 6 degrees +/- 8 degrees in Group A and 2 degrees 1 degrees in Group B (p < 0.002). No pin-track infections occurred in Group B. The average Harris hip score at six months was 62 +/- 19 points in Group A and 63 +/- 17 points in Group B.

CONCLUSIONS

This study showed that external fixation with hydroxyapatite-coated pins is an effective treatment for this fracture in this patient population. The operative time is brief, the blood loss is minimal, the fixation is adequate, and the reduction is maintained over time.

Для цитирования: Moroni Antonio, Faldini Cesare, Pegreffi Francesco, Hoang-Kim Amy, Vannini Francesca, Giannini Sandro. Dynamic hip screw compared with external fixation for treatment of osteoporotic pertrochanteric fractures. A prospective, randomized study.. The Journal of bone and joint surgery. American volume. 2005. DOI: 10.2106/jbjs.d.01789.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.