Absorbable Screws Versus Metallic Screws for Distal Tibiofibular Syndesmosis Injuries: A Meta-Analysis.

Xie Yuanlong, Cai Lin, Deng Zhouming, Ran Bing, Hu Chao

СтатьяМетаанализПоддержка исследования: вне правительства СШАОбзорПеревод в очереди

Аннотация

A meta-analysis was performed to investigate the outcomes between absorbable screw (AS) and metallic screw (MS) fixation for distal tibiofibular syndesmosis injuries (DTSIs). Randomized controlled trials comparing AS versus MS fixation in DTSIs were searched systematically, and the outcomes were analyzed using Review Manager Software, version 5.2. The risk ratio (RR) or mean difference with the 95% confidence interval (CI) was calculated using the fixed effects or random effects model. A total of 16 studies were included in the meta-analysis. No statistically significant difference was found between AS and MS fixation in excellent and good functional recovery rate (RR 1.11, 95% CI 1.00 to 1.23, I(2) = 60%, p = .06), infection (RR 1.66, 95% CI 0.73 to 3.79, I(2) = 0%, p = .23), incidence of pain (RR 0.68, 95% CI 0.24 to 1.92, I(2) = 12%, p = .47), screw broken (RR 0.31, 95% CI 0.03 to 2.93, I(2) = %, p = .31), heterotopic ossification (RR 1.93, 95% CI 0.21 to 17.62, I(2) = 51%, p = .56; 472 cases in 4 studies), fracture healing time (mean difference -1.88, 95% CI -3.51 to -0.26, I(2) = 93%, p = .02,), duration of operation time (mean difference 7.64, 95% CI -3.80 to 19.09, I(2) = 98%, p = .19). The incidence of foreign body reaction was higher with AS fixation (RR 6.07, 95% CI 2.54 to 14.50, I(2) = 0%, p < .001). The reoperation rate was higher with MS fixation (RR 0.08, 95% CI 0.03 to 0.18, I(2) = 77%, p < .01). The functional outcomes of AS were as good as those with MS for DTSIs. Other than the foreign body reaction, the complications occurring after AS fixation were not as serious as those with MS fixation. AS fixation might be a preferable alternative for reconstruction of DTSIs.

Для цитирования: Xie Yuanlong, Cai Lin, Deng Zhouming, Ran Bing, Hu Chao. Absorbable Screws Versus Metallic Screws for Distal Tibiofibular Syndesmosis Injuries: A Meta-Analysis.. The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons. 2015. DOI: 10.1053/j.jfas.2015.03.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.