m+Medelevator.RU
← Поиск публикаций
Archives of neurology · 2004

(123I) beta-CIT and single-photon emission computed tomographic imaging vs clinical evaluation in Parkinsonian syndrome: unmasking an early diagnosis.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jennings Danna L, Seibyl John P, Oakes David, Eberly Shirley, Murphy John, Marek Ken

Аннотация

BACKGROUND: The diagnosis of Parkinson disease is currently based on clinical evaluation. Functional neuroimaging using (123I) beta-carboxymethyoxy-3-beta-(4-iodophenyl) tropane (CIT) and single-photon emission computed tomography (SPECT) provides information on the integrity of the dopaminergic system in vivo and is a promising diagnostic tool in early Parkinson disease.

OBJECTIVE: To evaluate the diagnostic accuracy of dopamine transporter imaging using (123I)beta-CIT in patients with suspected parkinsonian syndrome (PS).

DESIGN: Community neurologists referred patients with suspected PS for imaging evaluation. Clinical diagnoses (positive PS or negative PS) were provided by the community neurologists and 2 movement disorder experts. We performed (123I)beta-CIT and SPECT imaging, and imaging diagnoses of positive PS or negative PS were assigned. A 6-month follow-up clinical diagnosis was assigned by a movement disorder expert blind to the imaging data, which represented the "gold standard" diagnosis for the study.

RESULTS: Thirty-five patients with suspected PS were referred. Diagnoses in question included essential tremor, psychogenic parkinsonism, drug-induced parkinsonism, primary dystonia, and unspecified gait disorder. Comparing the community neurologist's diagnoses at referral with the gold standard diagnosis, there was dis agreement in 25.7% (sensitivity, 0.92; specificity, 0.30). Comparing the quantitative imaging diagnoses with the gold standard, there was disagreement in 8.6% (sensitivity, 0.92; specificity, 1.00).

CONCLUSION: Performing (123I)beta-CIT and SPECT imaging at baseline appears to be a useful diagnostic tool to detect patients thought to have PS at baseline but who, after follow-up, do not have PS.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты